The knowledge and experience of the speakers at that conference was compiled in the book "Ultrasonically Guided Puncture Technique" published in Since then the Society has sponsored a conference at the same place in andthe latest conference being termed "Third International Ultrasonically guided puncture technique book on lnterventional Ultrasound".

If the address matches an existing account you will receive an email with instructions to reset your password.

COVID Resources. Reliable information about the coronavirus (COVID) is available from the World Health Organization (current situation, international travel).Numerous and frequently-updated resource results are available from this ’s WebJunction has pulled together information and resources to assist library staff as they consider how to handle coronavirus.

Ultrasonically guided puncture technique.

Download Ultrasonically guided puncture technique FB2

Copenhagen: Munksgaard and Baltimore: University Park Press, Google Scholar. Pedersen J F. Percutaneous puncture guided by ultrasonic multitransducer scanning. J Clin Ultrasound ; 5: Cited by: 4. The knowledge and experience of the speakers at that conference was compiled in the book "Ultrasonically Guided Puncture Technique" published in Since then the Society has sponsored a conference at the same place in andthe latest conference being termed "Third International Conference on lnterventional Ultrasound".Brand: Springer-Verlag Berlin Heidelberg.

Sixteen patients with osteolytic lesions of the chest wall underwent an ultrasonically guided puncture. There were 14 malignant and 2 benign lesions. Definitive specific histologic diagnosis was made by US in 14 of the 16 patients ( percent).

Of the 14 patients, 13 had malignant lesions and 1 had a benign lesion. Results. There was no statistically significant difference between the techniques for the mean (SD) number of trials to make a correct puncture, at () in the EN technique and () in the triangulation technique, or for the duration of each trial, at () s for the EN technique and () s for the triangulation technique.

The technique was improved by ultrasonically guided puncture, and the procedure was successful in 96% of the examinations. Collateral veins were visualized in 81% and esophageal or gastric varices in 69% of the patients with portal hypertension. The procedure was performed with little risk and discomfort, and portograms of high quality were.

The outer diameter of the endoscope is mm., and its end is round in shape. The trocar sheath has an air perfusion tap (Fig, lA and B). At the same time an attachment for the ultrasonic guidance of the trocar Presented in part at the 2nd International Conference on Ultrasonically Guided Puncture, Copenhagen, Denmark, Septem The ultrasonically guided puncture of the gallbladder in amimals.

A new methodological procedure for a simple and non-surgical collection of gallbladder bile. Klapdor R, Scherer K, Sepehr H, Klöppel G. In 4 piglets the gallbladder was punctured under sonographic control threetimes during a period of 46 days. In this study we compare the efficacy of ultrasonically guided percutaneous oocyte collection for in-vitro fertilization with ultrasonically guided transvaginal oocyte collection.

Forty-seven patients were prospectively randomized into two groups. Twenty-four patients underwent percutaneous follicle. Jorie Blvd., Suite Oak Brook, IL U.S.

Details Ultrasonically guided puncture technique PDF

& Canada: Outside U.S. & Canada: Denis Matter, MD, Gerard Spinelli, MD, and Pierre Warter, M D Pancreatography by direct puncture of the pancreatic duct guided by real-time ultrasound was used preoperatively to evaluate three cases of chronic pancreatitis.

Our experience of this technique went as anticipated without any complications. The association of ultrasonography, ultrasonically guided pancreatography, and aspiration. Sincewe have employed ultrasonically guided puncture method in our department and tried to apply this method to diagnosis and therapy in various urological diseases.

Concurrently, we have demonstrated the accuracy and safety of this puncture method. Ultrasonically guided percutaneous puncture technique Ultrasonically guided percutaneous puncture technique Holm, H.

H.; Rasmussen, S. N⊘Rby; Kvist Kristensen, J. Ultrasound provides anatomical sectional pictures of organs and lesions on the basis of which optimum direction and depth of puncture can be established. Abstract: Since the introduction of the B-mode puncture probe ultrasonically-guided puncture technique has rapidly developed.

It can not only show the general anatomic structure in every section, the focal location, action of the examined organ and its relation with the tissues around, but also the route the puncture needle takes and the location of the tip of the needle, so that the puncture.

The authors describe a cannula that has been modified to improve its visibility during ultrasonically guided biopsies of the brain. To enhance the echogenicity of the tip of the cannula, six parallel rings, to mm deep and to mm apart, were etched into the tip of the cannula. 07 Holm HH, Kristensen JK.

Ultrasonic guided puncture technique. Co-penhagen: Munksgaard; 08 Watanabe H, Wagai T, Takehara Y. (ed.) Ultrasonically guided punc-ture.

(In Japanese) 09 Goldberg BB, Pollack HM. Ultrasonic Aspiration Transducer.

Description Ultrasonically guided puncture technique EPUB

Radiology ; – 10 Saitoh M, Watanabe H, Ohe H et al. Ultrasonic real-time. Considering all these studies, US-guided axillary vein puncture has a success rate ranging from 80% to 99%.

25,38–40 Compared with other available access routes, this rate appears better than that reported for cephalic vein dissection (64–87%) 31,44,46,49 and similar to that reported for venography-guided axillary puncture (90–98%), 10, We report two cases of pneumothorax detected by echographic examination immediately after ultrasonically guided aspiration biopsy and confirmed by chest x-ray film.

The pneumothorax was characterized by the disappearance of the lung tumor. In the real-time image, the respiratory excursions of the visceral pleura also disappeared. In Jan Fog Pedersen of the Gentofte Hospital laboratory developed a technique for ultrasonically guided puncture using a linear array transducer.

In the group published one of the earliest mechanical sector real-time scanners in the world, consisting of a continuously rotating wheel with radially-mounted transducers.

Conclusion Chest US-guided biopsy in the diagnosis of peripheral lung lesions is a safe and fast procedure with high diagnostic yield and fewer complications. View full-text Article.

1) Makuuchi M: Illustrated Abdominal Ultrasonically Guided Puncture Techniques. Bunkodo, Tokyo 2) Watanabe H, Makuuchi M: Interventional Real -Time Ultrasound. Igaku -Shoin, Tokyo, 3) Makuuchi M: Abdominal Intraoperative Ultrasonography.

Igaku -shoin, T okyo,   Evaluation of an ultrasonically guided vein puncture technique for the placement of permanent pacing electrodes. Pacing Clin Electrophysiol. ; View in Article. puncture line from the point of insertion of the elec- trode to the mass lesion was determined.

Local anesthe- sia was induced along the puncture line by introducing % lidocaine from the insertion point at the skin to the peritoneum. Under ultrasonic guidance, a gauge cm guide needle was inserted in the vicinity of the tumor.

tadine, Sarget) during ultrasonically guided puncture were applied to the skin as a coupling medium. Methods andPuncture Technique The examination consisted of echographic investigation of each hemithorax (normal was scanned as a control) with patients seated CHEST I 5 MA~ Introduction and methods.

Blind subclavian venous puncture for endocardial lead placement can be complicated. 1 To minimize risk, an ultrasound-guided axillary vein approach has been developed. We have over patient experiences with this technique.

Klapdor, R., Scherer, K., Sepehr, H. and Kloppel, G. The ultrasonically guided puncture of the gallbladder in animals. A new methodological procedure for a simple and non-surgical collection of gallbladder bile.

Endoscopy 9, ' The ultrasonically guided puncture of the. Many interventional radiologists use the standard double-wall puncture technique, in which the needle may traverse other ducts or vessels, even when the target duct is punctured successfully.

To reduce the risk of hemorrhagic complications associated with the double-wall puncture technique, we tested a new single-wall puncture technique. The procedure was performed times in patients with hematologic malignancies and 1, times those with solid tumors.

A single-needle puncture of the vein was performed on 1, of 1, procedures (%); only eighteen attempts among 1, failed (%). Lumbar puncture (or spinal tap) is a procedure used to obtain cerebrospinal fluid for CSF analysis and to measure the opening pressure.

The lumbar puncture course uses an advanced simulator to teach students proper lumbar puncture technique in both the lateral decubitus postion and the sitting position and how to measure the opening pressure.[Ultrasonically guided puncture technique in urology using real-time scanner (author's transl)].

Saitoh M, Watanabe H, Ohe H, Tanaka S, Itakura Y, Date S. Nihon Hinyokika Gakkai zasshi. The Japanese Journal of Urology, 01 Jan70(1): Language: jpn.

Ultrasonically-guided fine needle aspiration biopsy of retroperitoneal mass lesions was performed in 96 consecutive patients.

The puncture was done transperitoneally, guided by a dynamic scanner. The procedure is rapid with a high diagnostic sensitivity and specificity.